YS6B-F Series
Rated Power: 6W
Input: 100-240V AC, 50 / 60Hz
Standby Power: ≤0.1W
Efficiency Level: DOE VI / COCV5
Protection: Short Circuit, OCP, OVP, OTP
Output: 5-36V
Home » Products » CATV Power Supplies » Switching Power Supplies » 6W CATV Power Supply
YS6B-F Series
Rated Power: 6W
Input: 100-240V AC, 50 / 60Hz
Standby Power: ≤0.1W
Efficiency Level: DOE VI / COCV5
Protection: Short Circuit, OCP, OVP, OTP
Output: 5-36V
Switching power adapter-wall plug type | |
Model information | YS6B-F |
Power: | 6W max. |
Input: | 100-240VAC 50/60Hz |
Output Voltage: | 5-36V |
Output Current: | 0.1-1.2A |
Input current: | 0.2A max. |
Inrush Current: | 90 Amps max. at 230VAC/50Hz,full load |
Leakage Current: | 0.25mA Max. at 264VAC input |
Energy Efficiency Level VI : | CoC 5 / DoE 6 / CEC VI |
No Load Power Consumption : | <0.15W |
Protections: | Short Circuit /Over Current /Over Voltage |
Short Circuit Protection (SCP): | Protection to Zero Voltage |
Over Voltage Protection (OVP): | ≤Vout*150% |
Over Current Protection (OCP): | 110%-180% |
Working TEMP.: | -20°C-50°C |
Working Humidity: | 5%-90% RH non-condensing |
Storage TEMP.,Humidity and altitude: | -40℃ ~+70°C ambient temperature and a 5% to 95% relative humidity range throughout an altitude range of -60 meters to +5000 meters AMSL. |
Input Plug: | EU 2pin |
Certificates and approvals: | GS ,CE EMC |
EMC Regulation compliance according to standard EN50083-2 | EN55024:1998 (Immunity) EN550022 (Conducted Disturbance at Mains Terminals) class B EN55013 (30MHz to 1000MHz , the “absorbing clamp method ” radiated disturbance power ) |
CE mark according to EN60950-1 Low Voltage Directive | Meets the Limits of EN61000-3-2 (Harmonic Current Emissions) EN61000-3-3 (Voltage Fluctuations + Flicker) EN61000-4-2 (Electrolitic Discharge –ESD) EN61000-4-3 (Radio-Frequency, Continuous Radiated Disturbance) EN61000-4-4 (Electrical Fast Transient /Burst Immunity) EN61000-4-5 (Lightening Surge) EN61000-4-6 (Conducted RF Immunity) EN6000-4-11 (AC input Voltage Periodic & Random Disturbance) |
RoHs compliance | ROHS directive ” 2011/65/EU “ |
Surge test | Phase angle: 90, 270 degrees, – Pulse Repetition rate: 60 sec. combination wave and ring wave ±6KV |
MTBF: | 100000 hours minimum at full load at 25℃ ambient |
Burn-in | The power supply shall be burn-in for 2 hours under nominal input and 100% load at ambient temperature of 25 degrees C |
Life: | continuously operation for 3-5 years alternative |
Dimension: | 62x48x38mm |
Weight: | 65g |
Packing: | 100PCS/CTN,40.5*26*30cm |
Address: Cuijia, Xidian Town, Ninghai, Ningbo, China 315613
Tel: +86-574-27862392
+86-574-27862331
E-mail: sales@yingjiao.com
© 2023 YINGJIAO Electrical. All rights reserved.